Telescoping aluminum chassis
Mechanical height indexes support sitting and standing-desk configurations from 17.5 to 24 inches. Four locking casters position the unit; stabilization feet carry the occupied load.
Desk Toilet One
Desk Toilet One fits beneath a fixed or height-adjustable desk. Its indexed aluminum chassis carries the load separately from the sealed C12 bay, air path, and control module.

457 × 495 mm · concept specification
445–610 mm · sitting and standing fit
14.4 kg · validation configuration
136 kg · engineering target
All dimensions, weights, and load values are concept specifications or engineering targets until validation is complete.
Physical operation
The fan, sensors, service indicators, and optional Cloud connection require power. The primary shutter, transport cap, and cartridge release do not. The manual carriage release is reserved for service.
Set one of the indexed chassis heights, engage all four caster locks, and lower the stabilization feet onto a level hard surface.
Opening the soft-close lid wakes the unit. Occupancy starts low-pressure airflow through the isolated cartridge chamber and AirSeal Filter.
When load is removed, the spring-closed shutter and double radial gasket close mechanically. A 90-second filtered purge follows.
At Collection ready, close and verify both cartridge closures before releasing the bay. Install a sanitized C12 and wait for the local seal and airflow checks.
Air enters around the seat opening, crosses the cartridge headspace, passes through the rear-right AirSeal cassette and downstream fan, then exits through the downward rear outlet.
The fan, sensors, indicators, purge, and Cloud sync stop. Remove load, close the lid, connect power, and wait for the restart purge and seal check. The shutter closes mechanically and the passive filtered pressure path remains available.
Do not begin a session while the device shows Charge required. Do not reuse or exchange the unit after a power interruption until the local readiness checks finish.
Chassis architecture
The load frame, cartridge bay, air path, and control module are separate assemblies. A technician can reach service components without opening the material path.
Mechanical height indexes support sitting and standing-desk configurations from 17.5 to 24 inches. Four locking casters position the unit; stabilization feet carry the occupied load.
The load surface mounts independently from the C12 chamber. Elastomer isolation and keyed components reduce transferred vibration while preventing incorrect cartridge installation.
Fill, seal, temperature, filter, battery, and service status are calculated locally. Desk Toilet Cloud is optional, and the unit includes no camera, microphone, biometric sensor, or body-weight estimation.

QuietCore acoustic architecture
Multi-density foam and a mass-loaded barrier surround the cartridge chamber. Elastomer mounts decouple the load surface and fan from the chassis. Tuned air channels keep the required airflow at a lower fan speed, and the stabilization feet reduce transfer into the floor and desk frame.
Engineering targetThe system-generated noise target is no more than 38 dBA at one meter under a planned controlled method with a 32 dBA ambient floor. User-originated sound is not included. Furnished-workspace results will depend on the room, flooring, desk, installation, and use.
Engineering target at 1 m
Target across 125 Hz–4 kHz
Planned controlled method
Begins after occupied state ends
AirSeal + C12
Low-pressure airflow draws chamber air through the AirSeal Filter. When load is removed, the cartridge closes inside the unit. Removal engages a second cap before the C12 leaves the keyed bay.
Activated carbon and zeolite filter chamber air before it reaches the fan and downward rear outlet. Differential pressure and a VOC proxy estimate remaining life; replacement is scheduled at 90 days or 120 sessions.
The reusable 12-liter shell has 9.6 liters of approved working volume. Every displayed percentage refers to that 9.6-liter limit. At 42% used, about 4.0 liters are estimated inside and 5.6 liters remain to Collection ready.
Collection ready occurs at 9.6 liters, after 10 calendar days from first use, or earlier under a temperature, seal, or route rule. Typical capacity is 18–24 combined-use sessions; estimated carry weight is 22–28 lb / 10–12.7 kg.
The C12 transport cap includes a passive filtered pressure-equalization membrane. “Sealed” means liquid-contained and tamper-evident, not hermetically gas-tight. AirSeal is not a room air purifier, pathogen-control device, or diagnostic instrument.
Approved use
The cartridge holds ordinary urine, feces, and standard dry toilet paper in one rigid, baffled sump. No separation, additive, stabilization, or treatment occurs in the unit.
After an accidental prohibited input, stop use, leave the C12 installed, report Inspection required, and identify the material to service. Do not remove, open, or empty the cartridge.
Cartridge exchange
Exchange is a physical two-hand procedure. Two independent mechanical indicators must confirm closure before the cartridge bay can release.
Place the sanitized C12, gloves, approved wipe, and empty rigid transit vessel beside the unit.
Close the lid, finish the 90-second purge, and check for temperature hold, leakage, puncture, or visible damage.
Move the recessed exchange lever to its stop. The shutter closes first; the transport cap engages second.
Check the green shutter flag and green cap band, then wait for the powered Seal confirmed state.
Press the bay release and slide the carriage forward. The release remains blocked until both mechanical closures are present.
Use the recessed handle and lower handhold. Lift the 22–28 lb / 10–12.7 kg cartridge upright with two hands.
Check and wipe only the exterior, then latch the C12 upright in its transit vessel for no more than 72 hours after sealed removal.
Insert the keyed sanitized cartridge to its stop, close the carriage, and wait for Ready after seal and airflow checks.
Leave the C12 in the bay, return the lever to its start position, and reseat once. If either indicator or the powered seal check fails again, restrict access and request service.
Removal is prohibited during a temperature hold, unconfirmed transport closure, visible damage or leakage, possible shutter contact at Capacity lock, or contamination below the radial gasket.
Fit, power, and service
DT One requires an unobstructed desk opening, a hard level floor, a grounded outlet, and separate clearance for the cartridge, filter, lid, and rear air outlet.
Provide an unobstructed 30 in wide × 24 in deep desk opening, 30 in wide × 18 in deep knee path, and at least 7 in above the adjusted seat. Desk aprons, crossbars, pedestals, drawers, and lift components may not enter those envelopes.
Leave 24 in for front extraction, 4 in at the rear outlet, 6 in on the filter side, and 2 in on the opposite side. The outlet must be within 6 ft from a grounded outlet.
Sitting configuration uses a 17.5–20.0 in seat height. Standing-desk configuration uses 21.5–24.0 in; it is an elevated seated position. Never move the desk while the unit is occupied.
Founding-pilot installations require a private home office, enclosed single-person office, approved private coworking office, or qualified lockable one-person booth. An exposed open-plan desk, cubicle, shared room, or freestanding screen is not sufficient.
Technical specifications
The launch hardware remains in engineering validation. The table identifies which values are concept specifications, engineering targets, or operating assumptions.
| Specification | Desk Toilet One | Status or condition |
|---|---|---|
| Footprint | 18.0 × 19.5 in / 457 × 495 mm | Concept specification |
| Indexed seat height | 17.5–24.0 in / 445–610 mm | Concept specification |
| Weight | 31.8 lb / 14.4 kg | Validation configuration |
| Maximum static load | 300 lb / 136 kg | Engineering target |
| Cartridge | C12 · 12 L nominal / 9.6 L approved working volume | Displayed percentage refers to the 9.6 L working volume |
| Collection ready | 9.6 L / 100% working volume | Also occurs earlier under age, temperature, seal, or route rules |
| Capacity lock | 10.8 L / 90% nominal volume | New use inhibited; customer removal may be prohibited |
| Typical cartridge yield | 18–24 combined-use sessions | Illustrative assumption; exchange may occur earlier |
| Collection-ready carry weight | 22–28 lb / 10–12.7 kg | Illustrative assumption; lift upright with two hands |
| Acoustic profile | At or below 38 dBA at 1 m | Engineering target under a planned controlled method |
| Battery | 74 Wh lithium iron phosphate | Up to 14 workdays under a typical profile, heating off |
| Charging | USB-C PD · 65 W maximum | Approximately 2.5 hours |
| Direct power | 100–240 V adapter through USB-C PD | Required for Studio seat regulation |
| Connectivity | 2.4 GHz Wi-Fi and Bluetooth LE | Optional Cloud sync; core closure remains mechanical |
| Filter interval | 90 days or 120 sessions | Whichever occurs first, subject to device condition |
| Operating environment | Indoor · 50–86°F / 10–30°C | Level hard surface with locks engaged |
| Exterior | Mineral-filled polymer over aluminum chassis | Chalk or Graphite finish |
| Interior | Removable chemical-resistant polypropylene surfaces | Wipe as needed; deeper clean weekly |
| Mobility | Four locking casters and stabilization feet | Roll only when unoccupied and cartridge-secured |
| Desk opening | 30 in wide × 24 in deep | Unobstructed development specification |
| Service clearance | Front 24 in · rear 4 in · filter side 6 in | Keep ventilation, cartridge, and filter paths clear |
| Limited warranty | Two years | Launch target; final terms pending |
Configurations
Both versions use the same chassis, C12 cartridge, QuietCore assembly, AirSeal Filter, local sensors, and mechanical closures. Each ships with two cartridges and can connect to Desk Toilet Cloud.
| Configuration | Desk Toilet One | Desk Toilet One Studio |
|---|---|---|
| Target price | $1,495 | $2,195 |
| Exterior | Mineral-filled polymer over aluminum | Cast-mineral panels with anodized details |
| Seat surface | Passive-temperature soft-close surface | 86–100°F regulation with 15-minute auto-off |
| Air handling | Occupied-state filtration and post-session purge | Occupied-state filtration, purge, and parked filtration |
| Illumination | Service and privacy status light | Integrated illumination and rear privacy strip |
| Power profile | Battery or USB-C direct power | Direct power required for heating |
| Finishes | Chalk or Graphite | Chalk or Graphite with anodized detail set |
Target pricing and configuration are subject to engineering validation, supply, final commercial terms, and regional service eligibility.
Founding pilot · Targeting 2027
The access list is used for regional availability, configuration updates, and collection eligibility. There is no charge today, and no shipment date has been assigned.